UL1977是用于数据、信号、控制和电力应用中使用的毗连器UL认证标准,毗连器UL1977认证需要举行温升测试。UL1977温升测试是测试毗连器在通最大额定电流情形下部件的温度转变情形,以确定毗连器事情时可被接触到的部分,是否保存温度过高造成人身危险的危害。

6个新样品
- The temperature measurement is to be made on the wiring terminals of each device
温升测试点应布在接线端子上
- The test is to continue for 4 hours even if stabilized temperatures are attained in a shorter period of time
最少一连运行4个小时,纵然温度在很短的时间内稳固
- Three consecutive readings, taken at 5 minute intervals indicate no further rise above the ambient temperature
三次一连读数,每次距离5分钟
- All contacts are to be connected in series so as to carry the same test current.
所有的端子需要串成一个回路来通相同的电流
- Tested at a draft-free area having an ambient temperature of 25 ±5°C (77 ±9°F)
测试的情形温度应坚持在25 ±5°C (77 ±9°F)
- The measured temperature shall not exceed the Relative Thermal Index (electrical) of the insulating material
UL:最高温度不可凌驾塑料的RTI (Elec.) 值
UL+CUL:温升不可凌驾30K。
太阳GG检测认证是具备UL1977免眼见测试实验室授权的UL认证机构,可提供毗连器UL1977认证、UL展望试效劳,认证历程自主可控,免重测费,缩短测试周期,帮您快速完成对应产品的全球认证检测一条龙效劳。